Powercom SMK-2000A, 2000VA, 6+0 Outlets

Price: $574.49
Product prices and availability are accurate as of 2017-08-17 00:34:00 EDT and are subject to change. Any price and availability information displayed on http://www.amazon.com/ at the time of purchase will apply to the purchase of this product.
Availability: Not Available Discontinued - Unfortunately this product has been discontinued and we will not be receiving any more stock. Click here for alternative products.
CERTAIN CONTENT THAT APPEARS ON THIS SITE COMES FROM AMAZON SERVICES LLC. THIS CONTENT IS PROVIDED 'AS IS' AND IS SUBJECT TO CHANGE OR REMOVAL AT ANY TIME.

Manufacturer Description

AC INPUT AC Input Capacity on Battery : 2000VA AC Input Voltage (+/-) : 25% at line input AC Input Frequency : 50 or 60 Hz+/-5% (auto sensing) AC OUTPUT AC Output Voltage : Pure sine wave at +/-5% of nominal, -10% of nominal after low battery warning AC Output Frequency : 50 or 60 Hz +/- 0.5% AC Output Voltage Regulation : AVR automatically increase output voltage 15% above input voltage if -9% to -25% of nominal. AVR decrease output voltage 15% below input voltage if +9% to +25% of nominal PROTECTION Protection Spike : 320 Joules, 2ms Protection EMI/RFI : 10dB at 0.15 MHz, 50 dB at 30 MHz Protection Overload : UPS automatic shutdown if overload exceeds 110% nominal at 20 sec and 125% at 5 sec Protection Transfer Time : 2/4 milliseconds (typical), including detection time Protection Short Protection : UPS output cut off immediately or input fuse( or breaker) protection BATTERY Battery Type : Hot swappable, sealed, maintenance-free lead acid, with 3 - 6 year lifetime Battery Typical : 4 hours (to 90% of full capacity) Battery Protection : Automatic self-test & discharge protection, replace battery indicator Battery Run Time : ~ 120 minutes PHYSICAL Weight : 30Kg (66lbs) Dimension : 170x450x226mm (6.7x17.7x8.9") INDICATOR LCD Indicators Status Indicate line, bypass, inv, backup, fault, bat capacity, load capacity, I/P frequency, O/P voltage, O/P frequency, inside temperature, fault status, load ALARM Alarm Battery Backup : Slow beeping sound (about 0.25 Hz) Alarm Battery Low : Rapid beeping sound (about 1.00Hz) Alarm Overload : Continue beeping sound INTERFACE Interface Dry Contact : Sends AC fail and battery low signals, and receives shutdown signal from computer Interface RS-232 : Detect battery low, Schedule UPS on/off, AC input/output power status display Interface Option : Novell, SNMP, Windows NT, Window 95/98/2000/ME/XP/7/8 ENVIRONMENT Environment Ambient : 3,500

Write a Review